Schema Tinnitus-270-500.xsd


schema location:  ..\Tinnitus-270-500.xsd
attribute form default:  unqualified
element form default:  qualified
targetNamespace:  http://www.himsa.com/measurement/Tinnitus/500
 
Elements  Complex types  Simple types 
TinnitusMeasurementData  Bandwidth_Type  SignalOutput_Type 
Intensity_Type  SignalUnit_Type 
MeasurementConditions_Type  TinnitusInhibitionSucess_Type 
MeasurementEquipment_Type  TinnitusMatchSucess_Type 
MeasurementFrequencyPoint_Type  TinnitusPerceptionLocation_Type 
MeasurementIntensityPoint_Type  TinnitusTemporalCharacteristic_Type 
MinimumMaskingLevel_Type  Transducer_Type 
ResidualInhibition_Type 
Signal_Type 
TinnitusLoudnessMatch_Type 
TinnitusMeasurementNotes_Type 
TinnitusPitchMatch_Type 


element TinnitusMeasurementData
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p1.png
namespace http://www.himsa.com/measurement/Tinnitus/500
properties
content complex
children TinnitusMeasurementNotes TinnitusMeasurementEquipment TinnitusPitchMatch TinnitusLoudnessMatch MinimumMaskingLevel ResidualInhibition
attributes
Name  Type  Use  Default  Fixed  annotation
Versionderived by: xs:integerrequired    500  
documentation
Version of this data standard
annotation
documentation
ROOT ELEMENT

December 15 2022

See REV history below

Important: All XML data must be encoded using UTF-8.

For software using this data standard:
In order not to waste space in the NOAH database it is not legal to save empty elements. <Element/>The information in this document is subject to change according to the review policies established by HIMSA II.

HIMSA II MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OR SUITABILITY FOR A PARTICULAR PURPOSE. HIMSA shall not be liable for errors contained herein or for incidental consequential damages in connection with the supply of, performance of, or use of this material.

This document contains proprietary information that is protected by copyright. All rights are reserved. No parts of this document may be photocopied, reproduced or distributed to Non-HIMSA member companies. without the prior permission of HIMSA II.

REV History:
Revision 1: December 15 2022:
- First release
 
Copyright © 2022 HIMSA II  K/S
documentation
Tinnitus measurements that can be used to quantify subjective tinnitus measurements.
source <xs:element name="TinnitusMeasurementData">
 
<xs:annotation>
   
<xs:documentation>ROOT ELEMENT

December 15 2022

See REV history below

Important: All XML data must be encoded using UTF-8.

For software using this data standard:
In order not to waste space in the NOAH database it is not legal to save empty elements.
<Element/>The information in this document is subject to change according to the review policies established by HIMSA II.

HIMSA II MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OR SUITABILITY FOR A PARTICULAR PURPOSE. HIMSA shall not be liable for errors contained herein or for incidental consequential damages in connection with the supply of, performance of, or use of this material.

This document contains proprietary information that is protected by copyright. All rights are reserved. No parts of this document may be photocopied, reproduced or distributed to Non-HIMSA member companies. without the prior permission of HIMSA II.

REV History:
Revision 1: December 15 2022:
- First release
 
Copyright © 2022 HIMSA II  K/S
</xs:documentation>
   
<xs:documentation>Tinnitus measurements that can be used to quantify subjective tinnitus measurements.</xs:documentation>
 
</xs:annotation>
 
<xs:complexType>
   
<xs:sequence>
     
<xs:element name="TinnitusMeasurementNotes" type="TinnitusMeasurementNotes_Type" minOccurs="0">
       
<xs:annotation>
         
<xs:documentation>Notes added to the Tinnitus Measurement</xs:documentation>
       
</xs:annotation>
     
</xs:element>
     
<xs:element name="TinnitusMeasurementEquipment" type="MeasurementEquipment_Type" minOccurs="0">
       
<xs:annotation>
         
<xs:documentation>The Tinnitus Measurement Equipment</xs:documentation>
       
</xs:annotation>
     
</xs:element>
     
<xs:element name="TinnitusPitchMatch" type="TinnitusPitchMatch_Type" minOccurs="0" maxOccurs="unbounded">
       
<xs:annotation>
         
<xs:documentation>(TPM) Test attempt to determine the frequency best matching the tinnitus</xs:documentation>
       
</xs:annotation>
     
</xs:element>
     
<xs:element name="TinnitusLoudnessMatch" type="TinnitusLoudnessMatch_Type" minOccurs="0" maxOccurs="unbounded">
       
<xs:annotation>
         
<xs:documentation>(TLM) Test attempt to determine loudness of the tinnitus</xs:documentation>
       
</xs:annotation>
     
</xs:element>
     
<xs:element name="MinimumMaskingLevel" type="MinimumMaskingLevel_Type" minOccurs="0" maxOccurs="unbounded">
       
<xs:annotation>
         
<xs:documentation>The minimum level to mask Tinnitus (MML). Test attempt to determine the lowest level at which a standard band of noise "covered" the tinnitus</xs:documentation>
       
</xs:annotation>
     
</xs:element>
     
<xs:element name="ResidualInhibition" type="ResidualInhibition_Type" minOccurs="0" maxOccurs="unbounded">
       
<xs:annotation>
         
<xs:documentation>Tinnitus loudness suppression after exposure to a stimulus</xs:documentation>
       
</xs:annotation>
     
</xs:element>
   
</xs:sequence>
   
<xs:attribute name="Version" use="required" fixed="500">
     
<xs:annotation>
       
<xs:documentation>Version of this data standard
</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:integer">
         
<xs:minInclusive value="500"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:attribute>
 
</xs:complexType>
</xs:element>

attribute TinnitusMeasurementData/@Version
type restriction of xs:integer
properties
isRef 0
fixed 500
use required
facets
Kind Value annotation 
minInclusive 500 
annotation
documentation
Version of this data standard
source <xs:attribute name="Version" use="required" fixed="500">
 
<xs:annotation>
   
<xs:documentation>Version of this data standard
</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:integer">
     
<xs:minInclusive value="500"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:attribute>

element TinnitusMeasurementData/TinnitusMeasurementNotes
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p2.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusMeasurementNotes_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children TinnitusPerceptionLocation TinnitusTemporalCharacteristic OtherMeasurementNotes
annotation
documentation
Notes added to the Tinnitus Measurement
source <xs:element name="TinnitusMeasurementNotes" type="TinnitusMeasurementNotes_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Notes added to the Tinnitus Measurement</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusMeasurementData/TinnitusMeasurementEquipment
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p3.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementEquipment_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children AudiometerMakeModel AudiometerSerialNumber AudiometerLastCalibrationDate
annotation
documentation
The Tinnitus Measurement Equipment
source <xs:element name="TinnitusMeasurementEquipment" type="MeasurementEquipment_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The Tinnitus Measurement Equipment</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusMeasurementData/TinnitusPitchMatch
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p4.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusPitchMatch_Type
properties
isRef 0
minOcc 0
maxOcc unbounded
content complex
children MeasurementConditions MeasurementPoint MatchingSuccess
annotation
documentation
(TPM) Test attempt to determine the frequency best matching the tinnitus
source <xs:element name="TinnitusPitchMatch" type="TinnitusPitchMatch_Type" minOccurs="0" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>(TPM) Test attempt to determine the frequency best matching the tinnitus</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusMeasurementData/TinnitusLoudnessMatch
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p5.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusLoudnessMatch_Type
properties
isRef 0
minOcc 0
maxOcc unbounded
content complex
children MeasurementConditions MeasurementPoint MatchingSuccess
annotation
documentation
(TLM) Test attempt to determine loudness of the tinnitus
source <xs:element name="TinnitusLoudnessMatch" type="TinnitusLoudnessMatch_Type" minOccurs="0" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>(TLM) Test attempt to determine loudness of the tinnitus</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusMeasurementData/MinimumMaskingLevel
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p6.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MinimumMaskingLevel_Type
properties
isRef 0
minOcc 0
maxOcc unbounded
content complex
children MeasurementConditions MeasurementPoint MatchingSuccess
annotation
documentation
The minimum level to mask Tinnitus (MML). Test attempt to determine the lowest level at which a standard band of noise "covered" the tinnitus
source <xs:element name="MinimumMaskingLevel" type="MinimumMaskingLevel_Type" minOccurs="0" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>The minimum level to mask Tinnitus (MML). Test attempt to determine the lowest level at which a standard band of noise "covered" the tinnitus</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusMeasurementData/ResidualInhibition
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p7.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type ResidualInhibition_Type
properties
isRef 0
minOcc 0
maxOcc unbounded
content complex
children MeasurementConditions SignalIntensity StimulusExposureTime InhibitionTime PulseDuration GapDuration NumberOfCycles InhibitionSuccess PerceptionLocation
annotation
documentation
Tinnitus loudness suppression after exposure to a stimulus
source <xs:element name="ResidualInhibition" type="ResidualInhibition_Type" minOccurs="0" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>Tinnitus loudness suppression after exposure to a stimulus</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType Bandwidth_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p8.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children UpperLimit UpperSlope PlateauSlope LowerLimit LowerSlope
used by
element MeasurementFrequencyPoint_Type/StimulusBandwidth
annotation
documentation
The width of the shaped noise defined by upper and lower limits in Hz.
source <xs:complexType name="Bandwidth_Type">
 
<xs:annotation>
   
<xs:documentation>The width of the shaped noise defined by upper and lower limits in Hz.</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="UpperLimit" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The upper cutoff frequency of the shaped noise</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="UpperSlope">
     
<xs:annotation>
       
<xs:documentation>The slope of the shaped noise from center frequency to upper cutoff frequency</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="PlateauSlope" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The slope at the center frequency</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="LowerLimit" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The lower cutoff frequency of the shaped noise</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="LowerSlope">
     
<xs:annotation>
       
<xs:documentation>The slope of the shaped noise from center frequency to lower cutoff frequency</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element Bandwidth_Type/UpperLimit
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p9.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The upper cutoff frequency of the shaped noise
source <xs:element name="UpperLimit" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The upper cutoff frequency of the shaped noise</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element Bandwidth_Type/UpperSlope
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p10.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The slope of the shaped noise from center frequency to upper cutoff frequency
source <xs:element name="UpperSlope">
 
<xs:annotation>
   
<xs:documentation>The slope of the shaped noise from center frequency to upper cutoff frequency</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element Bandwidth_Type/PlateauSlope
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p11.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The slope at the center frequency
source <xs:element name="PlateauSlope" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The slope at the center frequency</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element Bandwidth_Type/LowerLimit
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p12.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The lower cutoff frequency of the shaped noise
source <xs:element name="LowerLimit" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The lower cutoff frequency of the shaped noise</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element Bandwidth_Type/LowerSlope
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p13.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The slope of the shaped noise from center frequency to lower cutoff frequency
source <xs:element name="LowerSlope">
 
<xs:annotation>
   
<xs:documentation>The slope of the shaped noise from center frequency to lower cutoff frequency</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

complexType Intensity_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p14.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children Intensity Unit
used by
elements MeasurementFrequencyPoint_Type/MaskingIntensity MeasurementIntensityPoint_Type/MaskingIntensity MeasurementFrequencyPoint_Type/StimulusIntensity MeasurementIntensityPoint_Type/StimulusIntensity
annotation
documentation
Stimulus intensity and unit applied
source <xs:complexType name="Intensity_Type">
 
<xs:annotation>
   
<xs:documentation>Stimulus intensity and unit applied</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="Intensity">
     
<xs:annotation>
       
<xs:documentation>The signal intensity </xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:fractionDigits value="1"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="Unit" type="SignalUnit_Type">
     
<xs:annotation>
       
<xs:documentation>The unit used for the signal.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element Intensity_Type/Intensity
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p15.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
content simple
facets
Kind Value annotation 
fractionDigits 
annotation
documentation
The signal intensity
source <xs:element name="Intensity">
 
<xs:annotation>
   
<xs:documentation>The signal intensity </xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:fractionDigits value="1"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element Intensity_Type/Unit
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p16.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type SignalUnit_Type
properties
isRef 0
content simple
facets
Kind Value annotation 
enumeration HL 
enumeration SL 
enumeration SPL 
enumeration ABS 
annotation
documentation
The unit used for the signal.
source <xs:element name="Unit" type="SignalUnit_Type">
 
<xs:annotation>
   
<xs:documentation>The unit used for the signal.</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType MeasurementConditions_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p17.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children StimulusSignalType StimulusSignalOutput MaskingSignalType MaskingUnit MaskingSignalOutput StimulusTransducerType MaskingTransducerType StimulusTransducerDescription MaskingTransducerDescription StimulusAmplitudeModulation MaskingAmplitudeModulation StimulusBandwidthModulation MaskingBandwidthModulation StimulusFrequencyModulation MaskingFrequencyModulation
used by
elements TinnitusPitchMatch_Type/MeasurementConditions TinnitusLoudnessMatch_Type/MeasurementConditions MinimumMaskingLevel_Type/MeasurementConditions ResidualInhibition_Type/MeasurementConditions
annotation
documentation
Measuring Conditions for each measurement
source <xs:complexType name="MeasurementConditions_Type">
 
<xs:annotation>
   
<xs:documentation>Measuring Conditions for each measurement
</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="StimulusSignalType" type="Signal_Type">
     
<xs:annotation>
       
<xs:documentation>Stimulus signal is the sound being presented to the patient, in the ear being tested, that you want them to respond to. (e.g. Pure Tone)
Please note, for ResidualInhibition, the patient is submitted to a masking signal on the ear being tested. In this case the StimulusSignalType must be set in accordance to that masking signal.
</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="StimulusSignalOutput" type="SignalOutput_Type">
     
<xs:annotation>
       
<xs:documentation>This refers to the method used to deliver the sound the patient responds to.  The ear and way the sound is delivered is specified but not the exact device used to deliver that sound (e.g. left air conduction not TDH39)
See annotations for SignalOutput_Type for more information
</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MaskingSignalType" type="Signal_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>This is a sound used to stop the hearing in an ear that is not being tested from picking up the test signal. Often used when one ear is found to be significantly poorer than the other or for bone conduction testing.
The non test ear picking up the test tone is called crossover. Masking is presented to the non test ear.
</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MaskingUnit" type="SignalUnit_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The unit used for the masking signal.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MaskingSignalOutput" type="SignalOutput_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>This refers to the method used to deliver the masking sound to the patient. The ear and way the sound is delivered is specified but not the exact device used to deliver that sound. (e.g. left air conduction not TDH39)
See annotations for SignalOutput_Type for more information
</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="StimulusTransducerType" type="Transducer_Type" default="NoTransducer" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The device used to deliver sound to the test ear.
See annotations for Transducer_Type for more information
</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MaskingTransducerType" type="Transducer_Type" default="NoTransducer" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The device used to deliver sound to the non test ear.
See annotations for Transducer_Type for more information
</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="StimulusTransducerDescription" default="" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Optional description of the Transducer</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:string">
         
<xs:maxLength value="255"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingTransducerDescription" default="" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Optional description of the Transducer</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:string">
         
<xs:maxLength value="255"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="StimulusAmplitudeModulation" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The amplitude of the basic tone is modulated to produce a warble sound.
Measurement conditions typically used with DifferenceLimenIntensity.
</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:fractionDigits value="1"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingAmplitudeModulation" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Masking Amplitude Modulation is typically not used</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:fractionDigits value="1"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="StimulusBandwidthModulation" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>TBD! </xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:fractionDigits value="1"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingBandwidthModulation" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>TBD! </xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:fractionDigits value="1"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="StimulusFrequencyModulation" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The frequency of the basic tone is modulated by a lower frequency to produce a warble sound.
Measurement conditions typically used with DifferenceLimenFrequency
</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minInclusive value="0.00"/>
         
<xs:fractionDigits value="2"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingFrequencyModulation" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Masking Frequency Modulation is typically not used.</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minInclusive value="0.00"/>
         
<xs:fractionDigits value="2"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element MeasurementConditions_Type/StimulusSignalType
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p18.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Signal_Type
properties
isRef 0
content complex
children Signal_Types OtherSignalSpecification
annotation
documentation
Stimulus signal is the sound being presented to the patient, in the ear being tested, that you want them to respond to. (e.g. Pure Tone)
Please note, for ResidualInhibition, the patient is submitted to a masking signal on the ear being tested. In this case the StimulusSignalType must be set in accordance to that masking signal.
source <xs:element name="StimulusSignalType" type="Signal_Type">
 
<xs:annotation>
   
<xs:documentation>Stimulus signal is the sound being presented to the patient, in the ear being tested, that you want them to respond to. (e.g. Pure Tone)
Please note, for ResidualInhibition, the patient is submitted to a masking signal on the ear being tested. In this case the StimulusSignalType must be set in accordance to that masking signal.
</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementConditions_Type/StimulusSignalOutput
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p19.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type SignalOutput_Type
properties
isRef 0
content simple
facets
Kind Value annotation 
enumeration Unknown 
enumeration NoSignalOutput 
enumeration AirConductorLeft 
enumeration AirConductorRight 
enumeration AirConductorBinaural 
enumeration BoneConductorLeft 
enumeration BoneConductorRight 
enumeration BoneConductorBinaural 
enumeration FreeFieldLeft 
enumeration FreeFieldRight 
enumeration FreeFieldBinaural 
enumeration InsertPhoneLeft 
enumeration InsertPhoneRight 
enumeration InsertPhoneBinaural 
annotation
documentation
This refers to the method used to deliver the sound the patient responds to.  The ear and way the sound is delivered is specified but not the exact device used to deliver that sound (e.g. left air conduction not TDH39)
See annotations for SignalOutput_Type for more information
source <xs:element name="StimulusSignalOutput" type="SignalOutput_Type">
 
<xs:annotation>
   
<xs:documentation>This refers to the method used to deliver the sound the patient responds to.  The ear and way the sound is delivered is specified but not the exact device used to deliver that sound (e.g. left air conduction not TDH39)
See annotations for SignalOutput_Type for more information
</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementConditions_Type/MaskingSignalType
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p20.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Signal_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children Signal_Types OtherSignalSpecification
annotation
documentation
This is a sound used to stop the hearing in an ear that is not being tested from picking up the test signal. Often used when one ear is found to be significantly poorer than the other or for bone conduction testing.
The non test ear picking up the test tone is called crossover. Masking is presented to the non test ear.
source <xs:element name="MaskingSignalType" type="Signal_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>This is a sound used to stop the hearing in an ear that is not being tested from picking up the test signal. Often used when one ear is found to be significantly poorer than the other or for bone conduction testing.
The non test ear picking up the test tone is called crossover. Masking is presented to the non test ear.
</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementConditions_Type/MaskingUnit
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p21.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type SignalUnit_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration HL 
enumeration SL 
enumeration SPL 
enumeration ABS 
annotation
documentation
The unit used for the masking signal.
source <xs:element name="MaskingUnit" type="SignalUnit_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The unit used for the masking signal.</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementConditions_Type/MaskingSignalOutput
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p22.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type SignalOutput_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Unknown 
enumeration NoSignalOutput 
enumeration AirConductorLeft 
enumeration AirConductorRight 
enumeration AirConductorBinaural 
enumeration BoneConductorLeft 
enumeration BoneConductorRight 
enumeration BoneConductorBinaural 
enumeration FreeFieldLeft 
enumeration FreeFieldRight 
enumeration FreeFieldBinaural 
enumeration InsertPhoneLeft 
enumeration InsertPhoneRight 
enumeration InsertPhoneBinaural 
annotation
documentation
This refers to the method used to deliver the masking sound to the patient. The ear and way the sound is delivered is specified but not the exact device used to deliver that sound. (e.g. left air conduction not TDH39)
See annotations for SignalOutput_Type for more information
source <xs:element name="MaskingSignalOutput" type="SignalOutput_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>This refers to the method used to deliver the masking sound to the patient. The ear and way the sound is delivered is specified but not the exact device used to deliver that sound. (e.g. left air conduction not TDH39)
See annotations for SignalOutput_Type for more information
</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementConditions_Type/StimulusTransducerType
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p23.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Transducer_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
default NoTransducer
facets
Kind Value annotation 
enumeration Unknown 
enumeration NoTransducer 
enumeration Other 
enumeration HearingInstrument 
enumeration TDH39 
enumeration HDA200 
enumeration EARTONE3A 
enumeration DT48 
enumeration TDH49 
enumeration B71 
enumeration B72 
enumeration Beoton 
enumeration Holmberg 
enumeration EARTONE5A 
enumeration Eartone3A-ABR 
enumeration TDH50 
enumeration IP30 
enumeration IP30_10Ohm 
enumeration IP30_50Ohm 
enumeration DD45 
enumeration DD450 
enumeration B81 
enumeration DD65 
enumeration DD65v2 
enumeration Holmco_PD81 
enumeration Holmco_PD95 
enumeration HDA280 
enumeration HDA300 
enumeration BC-1 
enumeration BC-2 
annotation
documentation
The device used to deliver sound to the test ear.
See annotations for Transducer_Type for more information
source <xs:element name="StimulusTransducerType" type="Transducer_Type" default="NoTransducer" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The device used to deliver sound to the test ear.
See annotations for Transducer_Type for more information
</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementConditions_Type/MaskingTransducerType
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p24.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Transducer_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
default NoTransducer
facets
Kind Value annotation 
enumeration Unknown 
enumeration NoTransducer 
enumeration Other 
enumeration HearingInstrument 
enumeration TDH39 
enumeration HDA200 
enumeration EARTONE3A 
enumeration DT48 
enumeration TDH49 
enumeration B71 
enumeration B72 
enumeration Beoton 
enumeration Holmberg 
enumeration EARTONE5A 
enumeration Eartone3A-ABR 
enumeration TDH50 
enumeration IP30 
enumeration IP30_10Ohm 
enumeration IP30_50Ohm 
enumeration DD45 
enumeration DD450 
enumeration B81 
enumeration DD65 
enumeration DD65v2 
enumeration Holmco_PD81 
enumeration Holmco_PD95 
enumeration HDA280 
enumeration HDA300 
enumeration BC-1 
enumeration BC-2 
annotation
documentation
The device used to deliver sound to the non test ear.
See annotations for Transducer_Type for more information
source <xs:element name="MaskingTransducerType" type="Transducer_Type" default="NoTransducer" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The device used to deliver sound to the non test ear.
See annotations for Transducer_Type for more information
</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementConditions_Type/StimulusTransducerDescription
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p25.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:string
properties
isRef 0
minOcc 0
maxOcc 1
content simple
default <empty>
facets
Kind Value annotation 
maxLength 255 
annotation
documentation
Optional description of the Transducer
source <xs:element name="StimulusTransducerDescription" default="" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Optional description of the Transducer</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:string">
     
<xs:maxLength value="255"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementConditions_Type/MaskingTransducerDescription
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p26.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:string
properties
isRef 0
minOcc 0
maxOcc 1
content simple
default <empty>
facets
Kind Value annotation 
maxLength 255 
annotation
documentation
Optional description of the Transducer
source <xs:element name="MaskingTransducerDescription" default="" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Optional description of the Transducer</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:string">
     
<xs:maxLength value="255"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementConditions_Type/StimulusAmplitudeModulation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p27.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
fractionDigits 
annotation
documentation
The amplitude of the basic tone is modulated to produce a warble sound.
Measurement conditions typically used with DifferenceLimenIntensity.
source <xs:element name="StimulusAmplitudeModulation" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The amplitude of the basic tone is modulated to produce a warble sound.
Measurement conditions typically used with DifferenceLimenIntensity.
</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:fractionDigits value="1"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementConditions_Type/MaskingAmplitudeModulation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p28.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
fractionDigits 
annotation
documentation
Masking Amplitude Modulation is typically not used
source <xs:element name="MaskingAmplitudeModulation" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Masking Amplitude Modulation is typically not used</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:fractionDigits value="1"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementConditions_Type/StimulusBandwidthModulation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p29.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
fractionDigits 
annotation
documentation
TBD!
source <xs:element name="StimulusBandwidthModulation" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>TBD! </xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:fractionDigits value="1"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementConditions_Type/MaskingBandwidthModulation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p30.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
fractionDigits 
annotation
documentation
TBD!
source <xs:element name="MaskingBandwidthModulation" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>TBD! </xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:fractionDigits value="1"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementConditions_Type/StimulusFrequencyModulation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p31.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minInclusive 0.00 
fractionDigits 
annotation
documentation
The frequency of the basic tone is modulated by a lower frequency to produce a warble sound.
Measurement conditions typically used with DifferenceLimenFrequency
source <xs:element name="StimulusFrequencyModulation" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The frequency of the basic tone is modulated by a lower frequency to produce a warble sound.
Measurement conditions typically used with DifferenceLimenFrequency
</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minInclusive value="0.00"/>
     
<xs:fractionDigits value="2"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementConditions_Type/MaskingFrequencyModulation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p32.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minInclusive 0.00 
fractionDigits 
annotation
documentation
Masking Frequency Modulation is typically not used.
source <xs:element name="MaskingFrequencyModulation" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Masking Frequency Modulation is typically not used.</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minInclusive value="0.00"/>
     
<xs:fractionDigits value="2"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

complexType MeasurementEquipment_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p33.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children AudiometerMakeModel AudiometerSerialNumber AudiometerLastCalibrationDate
used by
element TinnitusMeasurementData/TinnitusMeasurementEquipment
annotation
documentation
The Measurement equipment used for the Tinnitus Measurement.
source <xs:complexType name="MeasurementEquipment_Type">
 
<xs:annotation>
   
<xs:documentation>The Measurement equipment used for the Tinnitus Measurement. </xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="AudiometerMakeModel" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The Manufacturer Make Model of the equipment used.</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:string">
         
<xs:maxLength value="255"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="AudiometerSerialNumber" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The Serial Number of the equipment used.</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:string">
         
<xs:maxLength value="41"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="AudiometerLastCalibrationDate" type="xs:dateTime" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Date of Last Calibration of the equipment used.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element MeasurementEquipment_Type/AudiometerMakeModel
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p34.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:string
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
maxLength 255 
annotation
documentation
The Manufacturer Make Model of the equipment used.
source <xs:element name="AudiometerMakeModel" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The Manufacturer Make Model of the equipment used.</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:string">
     
<xs:maxLength value="255"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementEquipment_Type/AudiometerSerialNumber
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p35.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:string
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
maxLength 41 
annotation
documentation
The Serial Number of the equipment used.
source <xs:element name="AudiometerSerialNumber" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The Serial Number of the equipment used.</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:string">
     
<xs:maxLength value="41"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementEquipment_Type/AudiometerLastCalibrationDate
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p36.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type xs:dateTime
properties
isRef 0
minOcc 0
maxOcc 1
content simple
annotation
documentation
Date of Last Calibration of the equipment used.
source <xs:element name="AudiometerLastCalibrationDate" type="xs:dateTime" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Date of Last Calibration of the equipment used.</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType MeasurementFrequencyPoint_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p37.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children StimulusFrequency StimulusIntensity StimulusBandwidth StimulusPulseDuration MaskingFrequency MaskingIntensity
used by
element TinnitusPitchMatch_Type/MeasurementPoint
annotation
documentation
Measurement Point with Frequency and optional Intensity, bandwidth and pulseDuration.
source <xs:complexType name="MeasurementFrequencyPoint_Type">
 
<xs:annotation>
   
<xs:documentation>Measurement Point with Frequency and optional Intensity, bandwidth and pulseDuration.</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="StimulusFrequency">
     
<xs:annotation>
       
<xs:documentation>The frequency at which the measurement was done.
##freq##
</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:integer">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="StimulusIntensity" type="Intensity_Type" minOccurs="0" maxOccurs="unbounded">
     
<xs:annotation>
       
<xs:documentation>The signal intensity and unit used for the stimulus signals.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="StimulusBandwidth" type="Bandwidth_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The width of the shaped noise defined by upper and lower limits in Hz. Center of noise defined in frequency and level in intensity.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="StimulusPulseDuration" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Duration of acoustic signal when using pulsed stimuli in seconds. </xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingFrequency" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The frequency at which the measurement was done.
##freq##
</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:integer">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingIntensity" type="Intensity_Type" minOccurs="0" maxOccurs="unbounded">
     
<xs:annotation>
       
<xs:documentation>The signal intensity and unit used for the stimulus signals.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element MeasurementFrequencyPoint_Type/StimulusFrequency
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p38.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:integer
properties
isRef 0
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The frequency at which the measurement was done.
##freq##
source <xs:element name="StimulusFrequency">
 
<xs:annotation>
   
<xs:documentation>The frequency at which the measurement was done.
##freq##
</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:integer">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementFrequencyPoint_Type/StimulusIntensity
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p39.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Intensity_Type
properties
isRef 0
minOcc 0
maxOcc unbounded
content complex
children Intensity Unit
annotation
documentation
The signal intensity and unit used for the stimulus signals.
source <xs:element name="StimulusIntensity" type="Intensity_Type" minOccurs="0" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>The signal intensity and unit used for the stimulus signals.</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementFrequencyPoint_Type/StimulusBandwidth
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p40.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Bandwidth_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children UpperLimit UpperSlope PlateauSlope LowerLimit LowerSlope
annotation
documentation
The width of the shaped noise defined by upper and lower limits in Hz. Center of noise defined in frequency and level in intensity.
source <xs:element name="StimulusBandwidth" type="Bandwidth_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The width of the shaped noise defined by upper and lower limits in Hz. Center of noise defined in frequency and level in intensity.</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementFrequencyPoint_Type/StimulusPulseDuration
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p41.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
Duration of acoustic signal when using pulsed stimuli in seconds.
source <xs:element name="StimulusPulseDuration" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Duration of acoustic signal when using pulsed stimuli in seconds. </xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementFrequencyPoint_Type/MaskingFrequency
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p42.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:integer
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The frequency at which the measurement was done.
##freq##
source <xs:element name="MaskingFrequency" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The frequency at which the measurement was done.
##freq##
</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:integer">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementFrequencyPoint_Type/MaskingIntensity
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p43.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Intensity_Type
properties
isRef 0
minOcc 0
maxOcc unbounded
content complex
children Intensity Unit
annotation
documentation
The signal intensity and unit used for the stimulus signals.
source <xs:element name="MaskingIntensity" type="Intensity_Type" minOccurs="0" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>The signal intensity and unit used for the stimulus signals.</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType MeasurementIntensityPoint_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p44.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children StimulusIntensity StimulusFrequency MaskingFrequency MaskingIntensity
used by
elements TinnitusLoudnessMatch_Type/MeasurementPoint MinimumMaskingLevel_Type/MeasurementPoint ResidualInhibition_Type/SignalIntensity
annotation
documentation
Measurement Point with Intensity and optional Frequency, bandwidth and pulseDuration.
source <xs:complexType name="MeasurementIntensityPoint_Type">
 
<xs:annotation>
   
<xs:documentation>Measurement Point with Intensity and optional Frequency, bandwidth and pulseDuration.</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="StimulusIntensity" type="Intensity_Type" maxOccurs="unbounded">
     
<xs:annotation>
       
<xs:documentation>The signal intensity and unit used for the stimulus signals.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="StimulusFrequency" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The frequency at which the measurement was done.
##freq##
</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:integer">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingFrequency" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The frequency at which the masking was done.
##freq##
</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:integer">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="MaskingIntensity" type="Intensity_Type" minOccurs="0" maxOccurs="unbounded">
     
<xs:annotation>
       
<xs:documentation>The signal intensity and unit used for the masking signal.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element MeasurementIntensityPoint_Type/StimulusIntensity
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p45.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Intensity_Type
properties
isRef 0
minOcc 1
maxOcc unbounded
content complex
children Intensity Unit
annotation
documentation
The signal intensity and unit used for the stimulus signals.
source <xs:element name="StimulusIntensity" type="Intensity_Type" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>The signal intensity and unit used for the stimulus signals.</xs:documentation>
 
</xs:annotation>
</xs:element>

element MeasurementIntensityPoint_Type/StimulusFrequency
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p46.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:integer
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The frequency at which the measurement was done.
##freq##
source <xs:element name="StimulusFrequency" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The frequency at which the measurement was done.
##freq##
</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:integer">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementIntensityPoint_Type/MaskingFrequency
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p47.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:integer
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The frequency at which the masking was done.
##freq##
source <xs:element name="MaskingFrequency" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The frequency at which the masking was done.
##freq##
</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:integer">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element MeasurementIntensityPoint_Type/MaskingIntensity
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p48.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type Intensity_Type
properties
isRef 0
minOcc 0
maxOcc unbounded
content complex
children Intensity Unit
annotation
documentation
The signal intensity and unit used for the masking signal.
source <xs:element name="MaskingIntensity" type="Intensity_Type" minOccurs="0" maxOccurs="unbounded">
 
<xs:annotation>
   
<xs:documentation>The signal intensity and unit used for the masking signal.</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType MinimumMaskingLevel_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p49.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children MeasurementConditions MeasurementPoint MatchingSuccess
used by
element TinnitusMeasurementData/MinimumMaskingLevel
annotation
documentation
(MML). Test attempt to determine the lowest level at which a standard band of noise "covered" the tinnitus
source <xs:complexType name="MinimumMaskingLevel_Type">
 
<xs:annotation>
   
<xs:documentation>(MML). Test attempt to determine the lowest level at which a standard band of noise "covered" the tinnitus</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Measurement Conditions for the Minimum Masking Level measurement</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MeasurementPoint" type="MeasurementIntensityPoint_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The Minimum Masking Level point</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MatchingSuccess" type="TinnitusMatchSucess_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The sucess of masking</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element MinimumMaskingLevel_Type/MeasurementConditions
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p50.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementConditions_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusSignalType StimulusSignalOutput MaskingSignalType MaskingUnit MaskingSignalOutput StimulusTransducerType MaskingTransducerType StimulusTransducerDescription MaskingTransducerDescription StimulusAmplitudeModulation MaskingAmplitudeModulation StimulusBandwidthModulation MaskingBandwidthModulation StimulusFrequencyModulation MaskingFrequencyModulation
annotation
documentation
Measurement Conditions for the Minimum Masking Level measurement
source <xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Measurement Conditions for the Minimum Masking Level measurement</xs:documentation>
 
</xs:annotation>
</xs:element>

element MinimumMaskingLevel_Type/MeasurementPoint
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p51.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementIntensityPoint_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusIntensity StimulusFrequency MaskingFrequency MaskingIntensity
annotation
documentation
The Minimum Masking Level point
source <xs:element name="MeasurementPoint" type="MeasurementIntensityPoint_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The Minimum Masking Level point</xs:documentation>
 
</xs:annotation>
</xs:element>

element MinimumMaskingLevel_Type/MatchingSuccess
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p52.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusMatchSucess_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Partial 
enumeration Complete 
enumeration NoResponse 
documentation
Reached the limits of equipment
enumeration CouldNotTest 
annotation
documentation
The sucess of masking
source <xs:element name="MatchingSuccess" type="TinnitusMatchSucess_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The sucess of masking</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType ResidualInhibition_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p53.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children MeasurementConditions SignalIntensity StimulusExposureTime InhibitionTime PulseDuration GapDuration NumberOfCycles InhibitionSuccess PerceptionLocation
used by
element TinnitusMeasurementData/ResidualInhibition
annotation
documentation
Tinnitus loudness suppression after exposure to a stimulus
source <xs:complexType name="ResidualInhibition_Type">
 
<xs:annotation>
   
<xs:documentation>Tinnitus loudness suppression after exposure to a stimulus</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Measurement Conditions for the Residual Inhibition measurement</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="SignalIntensity" type="MeasurementIntensityPoint_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The Stimulus Signal Level and frequescy used for Residual Inhibition measurements. Here the Signal is used to mask the tinnitus. Optional masking can be applied to the other ear.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="StimulusExposureTime" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The time, in seconds, the patient is exposed to the stimulus signal</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="InhibitionTime" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The time, in seconds, the masking is effective after it has been turned off</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="PulseDuration" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Duration of acoustic signal when using pulsed stimuli in seconds. </xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="GapDuration" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>the silence interval between the acoustic pulses in seconds</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:decimal">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="NumberOfCycles" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The time, in seconds, the masking is effective after it has been turned off</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:integer">
         
<xs:minExclusive value="0"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="InhibitionSuccess" type="TinnitusInhibitionSucess_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The sucess of Inhibition when applying masking</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="PerceptionLocation" type="TinnitusPerceptionLocation_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The percieved location of tinnitus</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element ResidualInhibition_Type/MeasurementConditions
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p54.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementConditions_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusSignalType StimulusSignalOutput MaskingSignalType MaskingUnit MaskingSignalOutput StimulusTransducerType MaskingTransducerType StimulusTransducerDescription MaskingTransducerDescription StimulusAmplitudeModulation MaskingAmplitudeModulation StimulusBandwidthModulation MaskingBandwidthModulation StimulusFrequencyModulation MaskingFrequencyModulation
annotation
documentation
Measurement Conditions for the Residual Inhibition measurement
source <xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Measurement Conditions for the Residual Inhibition measurement</xs:documentation>
 
</xs:annotation>
</xs:element>

element ResidualInhibition_Type/SignalIntensity
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p55.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementIntensityPoint_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusIntensity StimulusFrequency MaskingFrequency MaskingIntensity
annotation
documentation
The Stimulus Signal Level and frequescy used for Residual Inhibition measurements. Here the Signal is used to mask the tinnitus. Optional masking can be applied to the other ear.
source <xs:element name="SignalIntensity" type="MeasurementIntensityPoint_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The Stimulus Signal Level and frequescy used for Residual Inhibition measurements. Here the Signal is used to mask the tinnitus. Optional masking can be applied to the other ear.</xs:documentation>
 
</xs:annotation>
</xs:element>

element ResidualInhibition_Type/StimulusExposureTime
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p56.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The time, in seconds, the patient is exposed to the stimulus signal
source <xs:element name="StimulusExposureTime" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The time, in seconds, the patient is exposed to the stimulus signal</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element ResidualInhibition_Type/InhibitionTime
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p57.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The time, in seconds, the masking is effective after it has been turned off
source <xs:element name="InhibitionTime" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The time, in seconds, the masking is effective after it has been turned off</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element ResidualInhibition_Type/PulseDuration
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p58.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
Duration of acoustic signal when using pulsed stimuli in seconds.
source <xs:element name="PulseDuration" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Duration of acoustic signal when using pulsed stimuli in seconds. </xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element ResidualInhibition_Type/GapDuration
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p59.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:decimal
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
the silence interval between the acoustic pulses in seconds
source <xs:element name="GapDuration" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>the silence interval between the acoustic pulses in seconds</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:decimal">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element ResidualInhibition_Type/NumberOfCycles
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p60.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:integer
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
minExclusive 
annotation
documentation
The time, in seconds, the masking is effective after it has been turned off
source <xs:element name="NumberOfCycles" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The time, in seconds, the masking is effective after it has been turned off</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:integer">
     
<xs:minExclusive value="0"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element ResidualInhibition_Type/InhibitionSuccess
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p61.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusInhibitionSucess_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Partial 
enumeration Complete 
enumeration Combination 
enumeration Exacerbation 
enumeration NoResponse 
documentation
Reached the limits of equipment
enumeration CouldNotTest 
annotation
documentation
The sucess of Inhibition when applying masking
source <xs:element name="InhibitionSuccess" type="TinnitusInhibitionSucess_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The sucess of Inhibition when applying masking</xs:documentation>
 
</xs:annotation>
</xs:element>

element ResidualInhibition_Type/PerceptionLocation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p62.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusPerceptionLocation_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Central 
documentation
Central / Tinnitus is percived centrally in the head.     
enumeration Binaural 
documentation
Binaural / Tinnitus is percived in both ears not central.
enumeration MonauralRight 
documentation
MonArualRight / Tinnitus is percived in the right side of the head.     
enumeration MonauralLeft 
documentation
MonarualLeft / Tinnitus is percived in the right side of the head.
enumeration VariableLocation 
documentation
Tinnitus is percived in variable location
enumeration Unknown 
documentation
Tinnitus perception location cannot be decided
annotation
documentation
The percieved location of tinnitus
source <xs:element name="PerceptionLocation" type="TinnitusPerceptionLocation_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The percieved location of tinnitus</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType Signal_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p63.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children Signal_Types OtherSignalSpecification
used by
elements MeasurementConditions_Type/MaskingSignalType MeasurementConditions_Type/StimulusSignalType
annotation
documentation
The type of Signal used in the measurement.
source <xs:complexType name="Signal_Type">
 
<xs:annotation>
   
<xs:documentation>The type of Signal used in the measurement. </xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="Signal_Types">
     
<xs:annotation>
       
<xs:documentation>The Other type should be specified in the OtherSignalType element. </xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:annotation>
         
<xs:documentation>The type of Signal used in the measurement. The Other type should be specified in the OtherSignalType element. </xs:documentation>
       
</xs:annotation>
       
<xs:restriction base="xs:NMTOKEN">
         
<xs:enumeration value="Undefined">
           
<xs:annotation>
             
<xs:documentation>Unknown or unlisted signal type</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="NoSignal">
           
<xs:annotation>
             
<xs:documentation>No signal applied</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Tone">
           
<xs:annotation>
             
<xs:documentation>Sinusoidal tone</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Warble">
           
<xs:annotation>
             
<xs:documentation/>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="NarrowBandNoise">
           
<xs:annotation>
             
<xs:documentation>Narrow Band Noise</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="TwoTone"/>
         
<xs:enumeration value="WhiteNoise">
           
<xs:annotation>
             
<xs:documentation>white noise, constant power spectral density</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="PinkNoise">
           
<xs:annotation>
             
<xs:documentation>Pink Noise, each octave have an equal amount of noise power</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="RainbowPassage">
           
<xs:annotation>
             
<xs:documentation>Rainbow Passage signal</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="SpeechNoise">
           
<xs:annotation>
             
<xs:documentation>Speech with Noise</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="SpeechLike">
           
<xs:annotation>
             
<xs:documentation>Speech Like signal</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="LoudSpeech">
           
<xs:annotation>
             
<xs:documentation>Loud Speech</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="OwnVoice">
           
<xs:annotation>
             
<xs:documentation>Patients own voice</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Icra2pb1f1mn">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology,  2 persons babble, 1 female, 1 male, Normal effort.</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Icra3bsmnfn">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, 3 band speech modulated noise, Female weighted, Normal effort.</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Icra3bsmnmn">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, 3 band speech modulated noise, Male weighted, Normal effort.</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Icra6pbl">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, 6 persons babble, Loud effort</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Icra6pbn">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, 6 persons babble, Normal effort</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Icra6pbr">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, 6 persons babble, Raised effort</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="IcraUrgnml">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Loud effort</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="IcraUrgnmn">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Normal effort</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="IcraUrgnmr">
           
<xs:annotation>
             
<xs:documentation>International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Raised effort</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="SpeechNoiseILTASS">
           
<xs:annotation>
             
<xs:documentation>Speech Noise, the international long-term average speech spectrum </xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Aurins">
           
<xs:annotation>
             
<xs:documentation/>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="ISTS">
           
<xs:annotation>
             
<xs:documentation>International Speech Test Signal</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="EUHA-MPO">
           
<xs:annotation>
             
<xs:documentation>ISTS presented at 55 dB SPL together with short, loud sequential sinusoids.</xs:documentation>
           
</xs:annotation>
         
</xs:enumeration>
         
<xs:enumeration value="Other"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
   
<xs:element name="OtherSignalSpecification" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Description of the Signal used when referring to "Other" signal type.</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:string">
         
<xs:maxLength value="255"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element Signal_Type/Signal_Types
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p64.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
isRef 0
content simple
facets
Kind Value annotation 
enumeration Undefined 
documentation
Unknown or unlisted signal type
enumeration NoSignal 
documentation
No signal applied
enumeration Tone 
documentation
Sinusoidal tone
enumeration Warble 
enumeration NarrowBandNoise 
documentation
Narrow Band Noise
enumeration TwoTone 
enumeration WhiteNoise 
documentation
white noise, constant power spectral density
enumeration PinkNoise 
documentation
Pink Noise, each octave have an equal amount of noise power
enumeration RainbowPassage 
documentation
Rainbow Passage signal
enumeration SpeechNoise 
documentation
Speech with Noise
enumeration SpeechLike 
documentation
Speech Like signal
enumeration LoudSpeech 
documentation
Loud Speech
enumeration OwnVoice 
documentation
Patients own voice
enumeration Icra2pb1f1mn 
documentation
International Collegium of Rehabilitative Audiology,  2 persons babble, 1 female, 1 male, Normal effort.
enumeration Icra3bsmnfn 
documentation
International Collegium of Rehabilitative Audiology, 3 band speech modulated noise, Female weighted, Normal effort.
enumeration Icra3bsmnmn 
documentation
International Collegium of Rehabilitative Audiology, 3 band speech modulated noise, Male weighted, Normal effort.
enumeration Icra6pbl 
documentation
International Collegium of Rehabilitative Audiology, 6 persons babble, Loud effort
enumeration Icra6pbn 
documentation
International Collegium of Rehabilitative Audiology, 6 persons babble, Normal effort
enumeration Icra6pbr 
documentation
International Collegium of Rehabilitative Audiology, 6 persons babble, Raised effort
enumeration IcraUrgnml 
documentation
International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Loud effort
enumeration IcraUrgnmn 
documentation
International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Normal effort
enumeration IcraUrgnmr 
documentation
International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Raised effort
enumeration SpeechNoiseILTASS 
documentation
Speech Noise, the international long-term average speech spectrum
enumeration Aurins 
enumeration ISTS 
documentation
International Speech Test Signal
enumeration EUHA-MPO 
documentation
ISTS presented at 55 dB SPL together with short, loud sequential sinusoids.
enumeration Other 
annotation
documentation
The Other type should be specified in the OtherSignalType element.
source <xs:element name="Signal_Types">
 
<xs:annotation>
   
<xs:documentation>The Other type should be specified in the OtherSignalType element. </xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:annotation>
     
<xs:documentation>The type of Signal used in the measurement. The Other type should be specified in the OtherSignalType element. </xs:documentation>
   
</xs:annotation>
   
<xs:restriction base="xs:NMTOKEN">
     
<xs:enumeration value="Undefined">
       
<xs:annotation>
         
<xs:documentation>Unknown or unlisted signal type</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="NoSignal">
       
<xs:annotation>
         
<xs:documentation>No signal applied</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Tone">
       
<xs:annotation>
         
<xs:documentation>Sinusoidal tone</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Warble">
       
<xs:annotation>
         
<xs:documentation/>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="NarrowBandNoise">
       
<xs:annotation>
         
<xs:documentation>Narrow Band Noise</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="TwoTone"/>
     
<xs:enumeration value="WhiteNoise">
       
<xs:annotation>
         
<xs:documentation>white noise, constant power spectral density</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="PinkNoise">
       
<xs:annotation>
         
<xs:documentation>Pink Noise, each octave have an equal amount of noise power</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="RainbowPassage">
       
<xs:annotation>
         
<xs:documentation>Rainbow Passage signal</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="SpeechNoise">
       
<xs:annotation>
         
<xs:documentation>Speech with Noise</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="SpeechLike">
       
<xs:annotation>
         
<xs:documentation>Speech Like signal</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="LoudSpeech">
       
<xs:annotation>
         
<xs:documentation>Loud Speech</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="OwnVoice">
       
<xs:annotation>
         
<xs:documentation>Patients own voice</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Icra2pb1f1mn">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology,  2 persons babble, 1 female, 1 male, Normal effort.</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Icra3bsmnfn">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, 3 band speech modulated noise, Female weighted, Normal effort.</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Icra3bsmnmn">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, 3 band speech modulated noise, Male weighted, Normal effort.</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Icra6pbl">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, 6 persons babble, Loud effort</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Icra6pbn">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, 6 persons babble, Normal effort</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Icra6pbr">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, 6 persons babble, Raised effort</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="IcraUrgnml">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Loud effort</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="IcraUrgnmn">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Normal effort</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="IcraUrgnmr">
       
<xs:annotation>
         
<xs:documentation>International Collegium of Rehabilitative Audiology, Unmodulated random gaussian noise. Male weighted, Raised effort</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="SpeechNoiseILTASS">
       
<xs:annotation>
         
<xs:documentation>Speech Noise, the international long-term average speech spectrum </xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Aurins">
       
<xs:annotation>
         
<xs:documentation/>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="ISTS">
       
<xs:annotation>
         
<xs:documentation>International Speech Test Signal</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="EUHA-MPO">
       
<xs:annotation>
         
<xs:documentation>ISTS presented at 55 dB SPL together with short, loud sequential sinusoids.</xs:documentation>
       
</xs:annotation>
     
</xs:enumeration>
     
<xs:enumeration value="Other"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

element Signal_Type/OtherSignalSpecification
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p65.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:string
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
maxLength 255 
annotation
documentation
Description of the Signal used when referring to "Other" signal type.
source <xs:element name="OtherSignalSpecification" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Description of the Signal used when referring to "Other" signal type.</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:string">
     
<xs:maxLength value="255"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

complexType TinnitusLoudnessMatch_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p66.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children MeasurementConditions MeasurementPoint MatchingSuccess
used by
element TinnitusMeasurementData/TinnitusLoudnessMatch
annotation
documentation
(TLM) Test attempt to determine loudness of the tinnitus
source <xs:complexType name="TinnitusLoudnessMatch_Type">
 
<xs:annotation>
   
<xs:documentation>(TLM) Test attempt to determine loudness of the tinnitus</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Measurement Conditions for the Loudness Match measurement</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MeasurementPoint" type="MeasurementIntensityPoint_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The Loudness Match point</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MatchingSuccess" type="TinnitusMatchSucess_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The sucess of matching</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element TinnitusLoudnessMatch_Type/MeasurementConditions
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p67.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementConditions_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusSignalType StimulusSignalOutput MaskingSignalType MaskingUnit MaskingSignalOutput StimulusTransducerType MaskingTransducerType StimulusTransducerDescription MaskingTransducerDescription StimulusAmplitudeModulation MaskingAmplitudeModulation StimulusBandwidthModulation MaskingBandwidthModulation StimulusFrequencyModulation MaskingFrequencyModulation
annotation
documentation
Measurement Conditions for the Loudness Match measurement
source <xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Measurement Conditions for the Loudness Match measurement</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusLoudnessMatch_Type/MeasurementPoint
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p68.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementIntensityPoint_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusIntensity StimulusFrequency MaskingFrequency MaskingIntensity
annotation
documentation
The Loudness Match point
source <xs:element name="MeasurementPoint" type="MeasurementIntensityPoint_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The Loudness Match point</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusLoudnessMatch_Type/MatchingSuccess
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p69.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusMatchSucess_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Partial 
enumeration Complete 
enumeration NoResponse 
documentation
Reached the limits of equipment
enumeration CouldNotTest 
annotation
documentation
The sucess of matching
source <xs:element name="MatchingSuccess" type="TinnitusMatchSucess_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The sucess of matching</xs:documentation>
 
</xs:annotation>
</xs:element>

complexType TinnitusMeasurementNotes_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p70.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children TinnitusPerceptionLocation TinnitusTemporalCharacteristic OtherMeasurementNotes
used by
element TinnitusMeasurementData/TinnitusMeasurementNotes
annotation
documentation
The Measurement Notes structure is designed to hold the general notes from the Tinnitus Measurement.
source <xs:complexType name="TinnitusMeasurementNotes_Type">
 
<xs:annotation>
   
<xs:documentation>The Measurement Notes structure is designed to hold the general notes from the Tinnitus Measurement. </xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="TinnitusPerceptionLocation" type="TinnitusPerceptionLocation_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The perceived location of tinnitus</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="TinnitusTemporalCharacteristic" type="TinnitusTemporalCharacteristic_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The temporal characteristic of Tinnitus. How is the tinnitus experienced.</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="OtherMeasurementNotes" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Other notes. Eg. Tinnitus etiology information</xs:documentation>
     
</xs:annotation>
     
<xs:simpleType>
       
<xs:restriction base="xs:string">
         
<xs:maxLength value="255"/>
       
</xs:restriction>
     
</xs:simpleType>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element TinnitusMeasurementNotes_Type/TinnitusPerceptionLocation
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p71.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusPerceptionLocation_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Central 
documentation
Central / Tinnitus is percived centrally in the head.     
enumeration Binaural 
documentation
Binaural / Tinnitus is percived in both ears not central.
enumeration MonauralRight 
documentation
MonArualRight / Tinnitus is percived in the right side of the head.     
enumeration MonauralLeft 
documentation
MonarualLeft / Tinnitus is percived in the right side of the head.
enumeration VariableLocation 
documentation
Tinnitus is percived in variable location
enumeration Unknown 
documentation
Tinnitus perception location cannot be decided
annotation
documentation
The perceived location of tinnitus
source <xs:element name="TinnitusPerceptionLocation" type="TinnitusPerceptionLocation_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The perceived location of tinnitus</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusMeasurementNotes_Type/TinnitusTemporalCharacteristic
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p72.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusTemporalCharacteristic_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Steady 
documentation
Tinnitus is characterized as Steady sound     
enumeration Pulsatile 
documentation
Tinnitus is characterized as Pulsating
enumeration Fluctuating 
documentation
Tinnitus is characterized as Fluctuating but not pulsatile
enumeration Unknown 
documentation
Tinnitus characteristic cannot be decided
annotation
documentation
The temporal characteristic of Tinnitus. How is the tinnitus experienced.
source <xs:element name="TinnitusTemporalCharacteristic" type="TinnitusTemporalCharacteristic_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The temporal characteristic of Tinnitus. How is the tinnitus experienced.</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusMeasurementNotes_Type/OtherMeasurementNotes
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p73.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:string
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
maxLength 255 
annotation
documentation
Other notes. Eg. Tinnitus etiology information
source <xs:element name="OtherMeasurementNotes" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Other notes. Eg. Tinnitus etiology information</xs:documentation>
 
</xs:annotation>
 
<xs:simpleType>
   
<xs:restriction base="xs:string">
     
<xs:maxLength value="255"/>
   
</xs:restriction>
 
</xs:simpleType>
</xs:element>

complexType TinnitusPitchMatch_Type
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p74.png
namespace http://www.himsa.com/measurement/Tinnitus/500
children MeasurementConditions MeasurementPoint MatchingSuccess
used by
element TinnitusMeasurementData/TinnitusPitchMatch
annotation
documentation
(TPM) Test attempt to determine the frequency best matching the tinnitus
source <xs:complexType name="TinnitusPitchMatch_Type">
 
<xs:annotation>
   
<xs:documentation>(TPM) Test attempt to determine the frequency best matching the tinnitus</xs:documentation>
 
</xs:annotation>
 
<xs:sequence>
   
<xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>Measurement Conditions for the Pitch Match measurement</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MeasurementPoint" type="MeasurementFrequencyPoint_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The Pitch Match point</xs:documentation>
     
</xs:annotation>
   
</xs:element>
   
<xs:element name="MatchingSuccess" type="TinnitusMatchSucess_Type" minOccurs="0">
     
<xs:annotation>
       
<xs:documentation>The sucess of matching</xs:documentation>
     
</xs:annotation>
   
</xs:element>
 
</xs:sequence>
</xs:complexType>

element TinnitusPitchMatch_Type/MeasurementConditions
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p75.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementConditions_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusSignalType StimulusSignalOutput MaskingSignalType MaskingUnit MaskingSignalOutput StimulusTransducerType MaskingTransducerType StimulusTransducerDescription MaskingTransducerDescription StimulusAmplitudeModulation MaskingAmplitudeModulation StimulusBandwidthModulation MaskingBandwidthModulation StimulusFrequencyModulation MaskingFrequencyModulation
annotation
documentation
Measurement Conditions for the Pitch Match measurement
source <xs:element name="MeasurementConditions" type="MeasurementConditions_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>Measurement Conditions for the Pitch Match measurement</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusPitchMatch_Type/MeasurementPoint
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p76.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type MeasurementFrequencyPoint_Type
properties
isRef 0
minOcc 0
maxOcc 1
content complex
children StimulusFrequency StimulusIntensity StimulusBandwidth StimulusPulseDuration MaskingFrequency MaskingIntensity
annotation
documentation
The Pitch Match point
source <xs:element name="MeasurementPoint" type="MeasurementFrequencyPoint_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The Pitch Match point</xs:documentation>
 
</xs:annotation>
</xs:element>

element TinnitusPitchMatch_Type/MatchingSuccess
diagram Tinnitus-270-500_diagrams/Tinnitus-270-500_p77.png
namespace http://www.himsa.com/measurement/Tinnitus/500
type TinnitusMatchSucess_Type
properties
isRef 0
minOcc 0
maxOcc 1
content simple
facets
Kind Value annotation 
enumeration Partial 
enumeration Complete 
enumeration NoResponse 
documentation
Reached the limits of equipment
enumeration CouldNotTest 
annotation
documentation
The sucess of matching
source <xs:element name="MatchingSuccess" type="TinnitusMatchSucess_Type" minOccurs="0">
 
<xs:annotation>
   
<xs:documentation>The sucess of matching</xs:documentation>
 
</xs:annotation>
</xs:element>

simpleType SignalOutput_Type
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
base xs:NMTOKEN
used by
elements MeasurementConditions_Type/MaskingSignalOutput MeasurementConditions_Type/StimulusSignalOutput
facets
Kind Value annotation 
enumeration Unknown 
enumeration NoSignalOutput 
enumeration AirConductorLeft 
enumeration AirConductorRight 
enumeration AirConductorBinaural 
enumeration BoneConductorLeft 
enumeration BoneConductorRight 
enumeration BoneConductorBinaural 
enumeration FreeFieldLeft 
enumeration FreeFieldRight 
enumeration FreeFieldBinaural 
enumeration InsertPhoneLeft 
enumeration InsertPhoneRight 
enumeration InsertPhoneBinaural 
annotation
documentation
The Signal Output Type defines the means of presenting sound to the patient:
+ Air Conductor / headphones
+ Bone conductor / vibrator placed on the mastoid (HOCA-5 page 10)
+ Free Field / Loudspeakers in a special test room
+ Insert Phone / small foam tips used to deliver air conduction test.
It also defines which side (i.e. the persons left or right ear) is stimulated.
source <xs:simpleType name="SignalOutput_Type">
 
<xs:annotation>
   
<xs:documentation>The Signal Output Type defines the means of presenting sound to the patient:
+ Air Conductor / headphones
+ Bone conductor / vibrator placed on the mastoid (HOCA-5 page 10)
+ Free Field / Loudspeakers in a special test room
+ Insert Phone / small foam tips used to deliver air conduction test.
It also defines which side (i.e. the persons left or right ear) is stimulated.
</xs:documentation>
 
</xs:annotation>
 
<xs:restriction base="xs:NMTOKEN">
   
<xs:enumeration value="Unknown"/>
   
<xs:enumeration value="NoSignalOutput"/>
   
<xs:enumeration value="AirConductorLeft"/>
   
<xs:enumeration value="AirConductorRight"/>
   
<xs:enumeration value="AirConductorBinaural"/>
   
<xs:enumeration value="BoneConductorLeft"/>
   
<xs:enumeration value="BoneConductorRight"/>
   
<xs:enumeration value="BoneConductorBinaural"/>
   
<xs:enumeration value="FreeFieldLeft"/>
   
<xs:enumeration value="FreeFieldRight"/>
   
<xs:enumeration value="FreeFieldBinaural"/>
   
<xs:enumeration value="InsertPhoneLeft"/>
   
<xs:enumeration value="InsertPhoneRight"/>
   
<xs:enumeration value="InsertPhoneBinaural"/>
 
</xs:restriction>
</xs:simpleType>

simpleType SignalUnit_Type
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
base xs:NMTOKEN
used by
elements MeasurementConditions_Type/MaskingUnit Intensity_Type/Unit
facets
Kind Value annotation 
enumeration HL 
enumeration SL 
enumeration SPL 
enumeration ABS 
annotation
documentation
The decibel scale is used to measure the level of sound presented to the ears relative to a reference point.
HL - Hearing Level dB HL refers to the hearing ability of a person. Normal hearing is defined as 0 dB HL.
SL - Sensation level
SPL - Sound Pressure Level. dB SPL is the measured pressure relative to 20 micropascals.
ABS / Absolute Value of a measurement without any corrections
source <xs:simpleType name="SignalUnit_Type">
 
<xs:annotation>
   
<xs:documentation>The decibel scale is used to measure the level of sound presented to the ears relative to a reference point.
HL - Hearing Level dB HL refers to the hearing ability of a person. Normal hearing is defined as 0 dB HL.
SL - Sensation level
SPL - Sound Pressure Level. dB SPL is the measured pressure relative to 20 micropascals.
ABS / Absolute Value of a measurement without any corrections
</xs:documentation>
 
</xs:annotation>
 
<xs:restriction base="xs:NMTOKEN">
   
<xs:enumeration value="HL"/>
   
<xs:enumeration value="SL"/>
   
<xs:enumeration value="SPL"/>
   
<xs:enumeration value="ABS"/>
 
</xs:restriction>
</xs:simpleType>

simpleType TinnitusInhibitionSucess_Type
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
base xs:NMTOKEN
used by
element ResidualInhibition_Type/InhibitionSuccess
facets
Kind Value annotation 
enumeration Partial 
enumeration Complete 
enumeration Combination 
enumeration Exacerbation 
enumeration NoResponse 
documentation
Reached the limits of equipment
enumeration CouldNotTest 
annotation
documentation
How is the inhibition by masking of tinnitus working
source <xs:simpleType name="TinnitusInhibitionSucess_Type">
 
<xs:annotation>
   
<xs:documentation>How is the inhibition by masking of tinnitus working
</xs:documentation>
 
</xs:annotation>
 
<xs:restriction base="xs:NMTOKEN">
   
<xs:enumeration value="Partial">
     
<xs:annotation/>
   
</xs:enumeration>
   
<xs:enumeration value="Complete">
     
<xs:annotation/>
   
</xs:enumeration>
   
<xs:enumeration value="Combination">
     
<xs:annotation/>
   
</xs:enumeration>
   
<xs:enumeration value="Exacerbation">
     
<xs:annotation/>
   
</xs:enumeration>
   
<xs:enumeration value="NoResponse">
     
<xs:annotation>
       
<xs:documentation>Reached the limits of equipment</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="CouldNotTest">
     
<xs:annotation/>
   
</xs:enumeration>
 
</xs:restriction>
</xs:simpleType>

simpleType TinnitusMatchSucess_Type
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
base xs:NMTOKEN
used by
elements TinnitusPitchMatch_Type/MatchingSuccess TinnitusLoudnessMatch_Type/MatchingSuccess MinimumMaskingLevel_Type/MatchingSuccess
facets
Kind Value annotation 
enumeration Partial 
enumeration Complete 
enumeration NoResponse 
documentation
Reached the limits of equipment
enumeration CouldNotTest 
annotation
documentation
How is the tinnitus matching working
source <xs:simpleType name="TinnitusMatchSucess_Type">
 
<xs:annotation>
   
<xs:documentation>How is the tinnitus matching working
</xs:documentation>
 
</xs:annotation>
 
<xs:restriction base="xs:NMTOKEN">
   
<xs:enumeration value="Partial">
     
<xs:annotation/>
   
</xs:enumeration>
   
<xs:enumeration value="Complete">
     
<xs:annotation/>
   
</xs:enumeration>
   
<xs:enumeration value="NoResponse">
     
<xs:annotation>
       
<xs:documentation>Reached the limits of equipment</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="CouldNotTest">
     
<xs:annotation/>
   
</xs:enumeration>
 
</xs:restriction>
</xs:simpleType>

simpleType TinnitusPerceptionLocation_Type
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
base xs:NMTOKEN
used by
elements ResidualInhibition_Type/PerceptionLocation TinnitusMeasurementNotes_Type/TinnitusPerceptionLocation
facets
Kind Value annotation 
enumeration Central 
documentation
Central / Tinnitus is percived centrally in the head.     
enumeration Binaural 
documentation
Binaural / Tinnitus is percived in both ears not central.
enumeration MonauralRight 
documentation
MonArualRight / Tinnitus is percived in the right side of the head.     
enumeration MonauralLeft 
documentation
MonarualLeft / Tinnitus is percived in the right side of the head.
enumeration VariableLocation 
documentation
Tinnitus is percived in variable location
enumeration Unknown 
documentation
Tinnitus perception location cannot be decided
annotation
documentation
The perception of the location of Tinnitus
source <xs:simpleType name="TinnitusPerceptionLocation_Type">
 
<xs:annotation>
   
<xs:documentation>The perception of the location of Tinnitus</xs:documentation>
 
</xs:annotation>
 
<xs:restriction base="xs:NMTOKEN">
   
<xs:enumeration value="Central">
     
<xs:annotation>
       
<xs:documentation>Central / Tinnitus is percived centrally in the head.      </xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="Binaural">
     
<xs:annotation>
       
<xs:documentation>Binaural / Tinnitus is percived in both ears not central.</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="MonauralRight">
     
<xs:annotation>
       
<xs:documentation>MonArualRight / Tinnitus is percived in the right side of the head.      </xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="MonauralLeft">
     
<xs:annotation>
       
<xs:documentation>MonarualLeft / Tinnitus is percived in the right side of the head.</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="VariableLocation">
     
<xs:annotation>
       
<xs:documentation>Tinnitus is percived in variable location</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="Unknown">
     
<xs:annotation>
       
<xs:documentation>Tinnitus perception location cannot be decided</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
 
</xs:restriction>
</xs:simpleType>

simpleType TinnitusTemporalCharacteristic_Type
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
base xs:NMTOKEN
used by
element TinnitusMeasurementNotes_Type/TinnitusTemporalCharacteristic
facets
Kind Value annotation 
enumeration Steady 
documentation
Tinnitus is characterized as Steady sound     
enumeration Pulsatile 
documentation
Tinnitus is characterized as Pulsating
enumeration Fluctuating 
documentation
Tinnitus is characterized as Fluctuating but not pulsatile
enumeration Unknown 
documentation
Tinnitus characteristic cannot be decided
annotation
documentation
Record temporal characteristics of Tinnitus
source <xs:simpleType name="TinnitusTemporalCharacteristic_Type">
 
<xs:annotation>
   
<xs:documentation>Record temporal characteristics of Tinnitus</xs:documentation>
 
</xs:annotation>
 
<xs:restriction base="xs:NMTOKEN">
   
<xs:enumeration value="Steady">
     
<xs:annotation>
       
<xs:documentation>Tinnitus is characterized as Steady sound      </xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="Pulsatile">
     
<xs:annotation>
       
<xs:documentation>Tinnitus is characterized as Pulsating </xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="Fluctuating">
     
<xs:annotation>
       
<xs:documentation>Tinnitus is characterized as Fluctuating but not pulsatile</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
   
<xs:enumeration value="Unknown">
     
<xs:annotation>
       
<xs:documentation>Tinnitus characteristic cannot be decided</xs:documentation>
     
</xs:annotation>
   
</xs:enumeration>
 
</xs:restriction>
</xs:simpleType>

simpleType Transducer_Type
namespace http://www.himsa.com/measurement/Tinnitus/500
type restriction of xs:NMTOKEN
properties
base xs:NMTOKEN
used by
elements MeasurementConditions_Type/MaskingTransducerType MeasurementConditions_Type/StimulusTransducerType
facets
Kind Value annotation 
enumeration Unknown 
enumeration NoTransducer 
enumeration Other 
enumeration HearingInstrument 
enumeration TDH39 
enumeration HDA200 
enumeration EARTONE3A 
enumeration DT48 
enumeration TDH49 
enumeration B71 
enumeration B72 
enumeration Beoton 
enumeration Holmberg 
enumeration EARTONE5A 
enumeration Eartone3A-ABR 
enumeration TDH50 
enumeration IP30 
enumeration IP30_10Ohm 
enumeration IP30_50Ohm 
enumeration DD45 
enumeration DD450 
enumeration B81 
enumeration DD65 
enumeration DD65v2 
enumeration Holmco_PD81 
enumeration Holmco_PD95 
enumeration HDA280 
enumeration HDA300 
enumeration BC-1 
enumeration BC-2 
annotation
documentation
The device used to deliver sound (e.g. type of headphone TDH39)
A simple explanation for each type of device is provided below:
+ TDH39 / Supra aural headphones for air conduction tests
+ HDA200 / Supra aural headphones often used for extended high frequency air conduction testing
+ EarTone 3A / Insert earphones
+ DT48 / Supra aural headphones for air conduction tests
+ TDH49 /  Supra aural headphones for air conduction tests
+ B71 / Bone Conductor
+ B72 / Bone conductor
+ Beoton / specific set of headphones used with Beoton audiometers only
+ Holmberg / Supra aural headphones for air conduction tests usually used in noisier environments
+EARTONE5A,
+IP30,RadioEar  EARTONE3A version
+TDH50,
+Holmco_PD81,
+Holmco_PD95,
+DD45, RadioEar
+DD65, RadioEar DD45 with Peltor
+B81, RadioEar
+HDA280
+Eartone3A-ABR 
+HDA300 / Sennheiser (now EOL, but has been used in the current years)
+IP30_10Ohm / ABR from RadioEar
+IP30_50Ohm / ABR from RadioEar
+DD65v2 / RadioEar
+DD450 / RadioEar
+TDH39 / Telephonics
+BC-1 / Bone conducoter from BHM
+BC-2 / Bone conducoter from BHM
source <xs:simpleType name="Transducer_Type">
 
<xs:annotation>
   
<xs:documentation>The device used to deliver sound (e.g. type of headphone TDH39)
A simple explanation for each type of device is provided below:
+ TDH39 / Supra aural headphones for air conduction tests
+ HDA200 / Supra aural headphones often used for extended high frequency air conduction testing
+ EarTone 3A / Insert earphones
+ DT48 / Supra aural headphones for air conduction tests
+ TDH49 /  Supra aural headphones for air conduction tests
+ B71 / Bone Conductor
+ B72 / Bone conductor
+ Beoton / specific set of headphones used with Beoton audiometers only
+ Holmberg / Supra aural headphones for air conduction tests usually used in noisier environments
+EARTONE5A,
+IP30,RadioEar  EARTONE3A version
+TDH50,
+Holmco_PD81,
+Holmco_PD95,
+DD45, RadioEar
+DD65, RadioEar DD45 with Peltor
+B81, RadioEar
+HDA280
+Eartone3A-ABR 
+HDA300 / Sennheiser (now EOL, but has been used in the current years)
+IP30_10Ohm / ABR from RadioEar
+IP30_50Ohm / ABR from RadioEar
+DD65v2 / RadioEar
+DD450 / RadioEar
+TDH39 / Telephonics
+BC-1 / Bone conducoter from BHM
+BC-2 / Bone conducoter from BHM
</xs:documentation>
 
</xs:annotation>
 
<xs:restriction base="xs:NMTOKEN">
   
<xs:enumeration value="Unknown"/>
   
<xs:enumeration value="NoTransducer"/>
   
<xs:enumeration value="Other"/>
   
<xs:enumeration value="HearingInstrument"/>
   
<xs:enumeration value="TDH39"/>
   
<xs:enumeration value="HDA200"/>
   
<xs:enumeration value="EARTONE3A"/>
   
<xs:enumeration value="DT48"/>
   
<xs:enumeration value="TDH49"/>
   
<xs:enumeration value="B71"/>
   
<xs:enumeration value="B72"/>
   
<xs:enumeration value="Beoton"/>
   
<xs:enumeration value="Holmberg"/>
   
<xs:enumeration value="EARTONE5A"/>
   
<xs:enumeration value="Eartone3A-ABR"/>
   
<xs:enumeration value="TDH50"/>
   
<xs:enumeration value="IP30"/>
   
<xs:enumeration value="IP30_10Ohm"/>
   
<xs:enumeration value="IP30_50Ohm"/>
   
<xs:enumeration value="DD45"/>
   
<xs:enumeration value="DD450"/>
   
<xs:enumeration value="B81"/>
   
<xs:enumeration value="DD65"/>
   
<xs:enumeration value="DD65v2"/>
   
<xs:enumeration value="Holmco_PD81"/>
   
<xs:enumeration value="Holmco_PD95"/>
   
<xs:enumeration value="HDA280"/>
   
<xs:enumeration value="HDA300"/>
   
<xs:enumeration value="BC-1"/>
   
<xs:enumeration value="BC-2"/>
 
</xs:restriction>
</xs:simpleType>


XML Schema documentation generated by XMLSpy Schema Editor http://www.altova.com/xmlspy